WhatsApp Us Quick Call

Diesel Generators & Electrical Products

Authorized Dealer: DPK genset (10 – 250 KVA), Sterling (10 – 250 KVA) & Ashok Leyland (300 – 3000 KVA). Complete Power & Electrical Solutions.

Showing 6 of 6 products

Bulk / Custom Quote
Ashok Leyland 1010 kVA High Capacity Generator DG Set ★ Featured
1,010 kVA

Ashok Leyland 1010 kVA High Capacity Generator

Ashok Leyland · Leroy Somer Alt.
  • High Capacity
  • Dual Fuel Option
  • Remote Monitoring
Details
DPK 500 kVA Prime Power Generator DG Set ★ Featured
500 kVA

DPK 500 kVA Prime Power Generator

DPK · Stamford Alt.
  • Prime Power Rating
  • Turbo Charged
  • Paralleling Capability
Details
Ashok Leyland 250 kVA Generator Set DG Set ★ Featured
250 kVA

Ashok Leyland 250 kVA Generator Set

Ashok Leyland · Stamford Alt.
  • Ashok Leyland 6-Cylinder Engine
  • Auto Transfer Switch
  • Digital AMF
Details
DPK 125 kVA Industrial Generator Set DG Set ★ Featured
125 kVA

DPK 125 kVA Industrial Generator Set

DPK · Stamford Alt.
  • Heavy Duty
  • Water Cooled
  • Digital Control Panel
Details
Ashok Leyland 62.5 kVA Diesel Generator DG Set ★ Featured
63 kVA

Ashok Leyland 62.5 kVA Diesel Generator

Ashok Leyland · Leroy Somer Alt.
  • Ashok Leyland Engine
  • Leroy Somer Alternator
  • Auto Start
Details
DPK 10 kVA Silent Diesel Generator DG Set ★ Featured
10 kVA

DPK 10 kVA Silent Diesel Generator

DPK · Stamford Alt.
  • Silent Canopy
  • Fuel Efficient
  • Auto Start
Details

Diesel Generator (DG) Overview & Principles

A Diesel Generator (DG set) combines a heavy-duty diesel internal combustion engine with an electrical alternator to generate on-demand electrical power. It serves as an indispensable primary power source or automated emergency backup when the utility electrical grid fails.

1. Diesel Fuel Chemical energy stored in diesel fuel
2. Diesel Engine Combustion converts fuel to mechanical motion
3. Alternator Electromagnetic induction creates AC power
4. Electrical Power Clean 415V / 230V electricity to facility

Key Components of a Diesel Generator

Every Santech-supplied generator integrates Tier-1 OEM subsystems engineered for maximum thermal efficiency, low emissions, and continuous operating life.

1. Diesel Engine

The prime mover providing rotational shaft torque. Santech utilizes multi-cylinder, turbocharged, aftercooled diesel engines from world leaders (Cummins, Perkins, DPK, Volvo) with precise electronic governor control.

2. Alternator (Generator)

Converts mechanical rotational energy into clean electrical energy. Features brushless, self-excited 4-pole design with Class H insulation and digital Automatic Voltage Regulator (AVR) maintaining ±1% regulation.

3. Fuel System

Includes daily basefuel tank (8–24 hours continuous runtime), primary water separators, micro-particle fuel filters, mechanical/electronic high-pressure injection pumps, and return fuel lines.

4. Cooling & Exhaust System

Heavy-duty tropical radiator with belt-driven blower fan engineered for 50°C ambient temperatures, jacket water heating, expansion bellow, and residential acoustic exhaust silencer.

5. Control Panel + ATS

Microprocessor digital control module monitoring voltage, frequency, oil pressure, and coolant temperature, paired with an Automatic Transfer Switch (ATS) for instantaneous grid-to-DG changeover.

6. Acoustic Enclosure

Soundproof, weatherproof CRCA steel canopy lined with high-density flame-retardant rockwool and tuned acoustic baffles, ensuring whisper-quiet operation compliant with strict CPCB noise norms (75 dBA @ 1m).

Types & Configurations of DG Sets

Tailored mechanical configurations engineered to fit specific site boundaries, ambient conditions, and mobility demands.

Open (Frame Type)

Compact unhoused configuration designed for installation inside dedicated, acoustically treated indoor generator plant rooms with external ducting.

Soundproof / Acoustic

The industry standard silent canopy for outdoor rooftop or ground-level placement in noise-sensitive residential, hospital, and commercial complexes.

Container / Modular Type

Heavy-duty 20ft or 40ft ISO marine containerized enclosures designed for large multi-megawatt sets (1000–3000 kVA) with internal service corridors.

Skid / Base Mounted

Rigid structural channel-steel skid frame with built-in AVM (Anti-Vibration Mounts) allowing easy crane lifting and rapid plant room placement.

Portable / Trailer Mounted

Towable multi-axle road trailers with brakes, tail lamps, and cable reels for rapid mobile power dispatch at construction sites, mining, and outdoor events.

Applications Across Industries

Santech generators deliver reliable primary, prime, and critical standby power across India's most demanding sectors.

Residential & Housing Complexes

Uninterrupted power for elevators, common lighting, domestic water booster pumps, and fire protection systems across high-rise residential towers and township complexes.

Recommended: 25 kVA to 250 kVA

Commercial Buildings, Malls & Offices

Complete backup for centralized HVAC chillers, escalators, point-of-sale systems, IT desktop power, and emergency smoke extraction fans across corporate headquarters and retail malls.

Recommended: 250 kVA to 1500 kVA

Hospitals & Telecom Towers

Mission-critical zero-tolerance power continuity for life-support ventilators, operation theaters, MRI/CT scanners, and telecom switching centers with automated sub-10 second failover.

Recommended: 100 kVA to 1000 kVA

Data Centres & Laboratories

Tier-3 and Tier-4 data facility continuous ratings paired with precision air conditioning, harmonic filtration, and synchronizing parallel systems for pharmaceutical testing labs.

Recommended: 500 kVA to 3000 kVA

Factories & Industrial Plants

Heavy prime power handling high inductive motor starting loads, automated assembly lines, furnaces, and chemical reaction vessels with multi-megawatt synchronizing architectures.

Recommended: 250 kVA to 3000 kVA

Events & Construction Sites

Rugged mobile power for infrastructure civil projects, metro rail tunneling, road construction, temporary site offices, outdoor exhibitions, concerts, and broadcast broadcasts.

Recommended: 15 kVA to 500 kVA

Need a Generator or Electrical Service?

Our team is ready to assist you. Get a competitive quote within 24 hours.